Good to know
How the code is built
The encoder follows ISO/IEC 18004, the QR code standard. Your content is turned into UTF-8 bytes and stored in byte mode. The tool then picks the smallest of the 40 versions that fits, adds error correction and chooses the mask pattern that is easiest to scan. Each version is a square grid:
modules per side = 17 + 4 × version
So version 1 is 21 × 21 and version 40 is 177 × 177. A four-module quiet zone is added around the edge, which scanners need.
Error correction
| Level | Damage it can recover | Most bytes at version 40 |
|---|---|---|
| Low (L) | about 7% | 2,953 |
| Medium (M) | about 15% | 2,331 |
| Quartile (Q) | about 25% | 1,663 |
| High (H) | about 30% | 1,273 |
Worked example: https://brightloop.world/ is 25 bytes. At Medium it fits version 2 (25 × 25 modules); at High it needs version 4 (33 × 33). Higher correction makes a denser code, so use High only for codes that will be printed small, laminated or likely to get scratched. The status line under the code shows the version and grid size it chose.
What each type writes
- Email:
mailto:followed by the address. - Phone:
tel:followed by the digits and any leading +. Include the country code so it works abroad. - Wi-Fi:
WIFI:T:WPA;S:name;P:password;;, with special characters such as;and:escaped. Most phone cameras offer to join the network.
Printing tips
- Dark on light scans best. Light codes on dark backgrounds fail in many scanner apps, and the tool warns you.
- SVG stays sharp at any size; PNG suits screens and documents. The PNG size is rounded so every module is a whole number of pixels.
- Shorter content means bigger modules at the same print size, which scan from further away.
- Test with more than one phone, in the light where the code will hang.